Instruction manual
C-32
BreezeACCESS Version 4.3 System Manual
Manual Revision: 4.0
*MinorAlarmThreshold
710.3.3. 8.7.4.1.1.5
(*TrafficStatisticsEntry 5)
Applicable to IF-based AU only.
Read-write. The threshold for
activating a minor severity alarm for
the relevant statistics type. Another
prerequisite for activating the alarm
is that the difference between the
Traffic Statistics Current Rate and
the previous Traffic Statistics
Average Rate exceeds the Traffic
Statistics Minor Alarm Minimum
Delta.
Integer
1 – 100 (%)
*MajorAlarmThreshold
710.3.3. 8.7.4.1.1.6
(*TrafficStatisticsEntry 6)
Applicable to IF-based AU only.
Read-write. The threshold for
activating a major severity alarm for
the relevant statistics type.
Integer
1 – 100 (%)
*AURxPowerTest
710.3.3. 8.7.5
(*AUAlarms 5)
Applicable to IF-based AU only. AU
Alarms AU Rx Power Tests
parameters and measurement
results.
*AURxPowerAverageDelta
710.3.3. 8.7.5.1
(*AURxPowerTest 1)
Applicable to IF-based AU only.
Read-only. The average for all SUs
that responded to the last two
polling messages of the difference
between the last RSSI at the AU
and the previous (one before last)
RSSI. (A negative value indicates
that the average RSSI was
decreased).
DisplayString
-99 to 99 (dBm)
*AURxPowerDecreaseThreshold
710.3.3. 8.7.5.2
(*AURxPowerTest 2)
Applicable to IF-based AU only.
Read-write. The Minimum decrease
in the value of the AU Rx Power
Average Delta that will trigger an
alarm. (If the AU Rx Power
Decrease Threshold is +X, an alarm
will be generated if the AU Rx
Power Average Delta is smaller
than or equal to –X)
Integer
1 – 99 (dBm)
*SURxPowerTest
710.3.3. 8.7.6
(*AUAlarms 6
Applicable to IF-based AU only. AU
Alarms SU Rx Power Tests
parameters and measurement
results.
*SURxPowerAverageDelta
710.3.3. 8.7.6.1
(*SURxPowerTest 1)
Applicable to IF-based AU only.
Read-only. The average for all SUs
that responded to the last two
polling messages of the difference
between the last RSSI at the SU
and the previous (one before last)
RSSI. (A negative value indicates
that the average RSSI was
decreased).
DisplayString
-99 to 99 (dBm)
*SURxPowerDecreaseThreshold
710.3.3. 8.7.6.2
(*SURxPowerTest 2)
Applicable to IF-based AU only.
Read-write. The Minimum decrease
in the value of the SU Rx Power
Average Delta that will trigger an
alarm. (If the SU Rx Power
Decrease Threshold is +X, an alarm
will be generated if the SU Rx
Power Average Delta is smaller
than or equal to –X)
Integer
1 – 99 (dBm)
*RespondingSUs
710.3.3. 8.7.7
(*AUAlarms 7)
Applicable to IF-based AU only.
Responding SUs parameters.
*CurrentNumberOfRespondingSUs
710.3.3. 8.7.7.1
(*RespondingSUs 1)
Applicable to IF-based AU only.
Read-only. The number of SUs that
responded to the last polling
message.
Integer
na (255)
*AverageNumberOfRespondingSU
s
710.3.3. 8.7.7.2
(*RespondingSUs 2)
Applicable to IF-based AU only.
Read-only. The average number of
SUs that responded to polling
message since power-up or since
the AU Alarms Option was enabled.
Integer
na (255)
MIB Parameter
(Location in Parenthesis)
Description Values/Range