Instruction manual

Appendix C
C-19
BreezeACCESS Version 4.3 System Manual
*TransmitLevel
710.3.3. 6.24
(*AirInterface 24)
Applicable only to SU-I and AU-I
units with HW version D and higher.
Sets the level in dBm of the
transmitted power at the antenna
port.
Integer
0-21dBm
na (255)
* brzaccAtpc
710.3.3. 6.25
(*AirInterface 25)
ATPC Parameters
*AtpcOption
710.3.3. 6.25.1
(*Atpc 1)
Applicable to IF based units and SU-
R-3.5ab units only. Enabling/
disabling the ATPC Algorithm.
Integer
disable (0)
enable (1)
na (255)
*AtpcMaximumRSSI
710.3.3. 6.25.2
(*Atpc 2)
Applicable to IF based AU only.
Defines the maximum desired level
of the average RSSI at the AU.
Above this level, if *AtpcOption is
enabled, the AU will transmit ATPC
Power-Down messages to the
applicable SU. The
*AtpcMaximumRSSI cannot be lower
than *AtpcMinimumRSSI.
Display String
-100 to 0 [dBm]
AtpcMinimumRSSI
710.3.3. 6.25.3
(*Atpc 3)
Applicable to IF based AU only.
Defines the minimum desired level of
the average RSSI at the AU. Below
this level, if *AtpcOption is enabled,
the AU will transmit ATPC Power-Up
messages to the applicable SU. The
*AtpcMinimumRSSI cannot be
higher than *AtpcMaximumRSSI.
Display String
-100 to 0 [dBm]
AtpcMinimumIntervalBetweenMessage
s
710.3.3. 6.25.4
(*Atpc 4)
Applicable to IF based AU only. The
minimum interval between two
consecutive AU to SU ATPC Power-
Up/Power-Down messages.
Integer
0 to 3600 (seconds)
na (255)
RssiMemoryFactor
710.3.3. 6.25.5
(*Atpc 5)
Applicable to IF based AU only. The
weight of history in average RSSI
calculation. The higher is the value,
the higher is the weight of history
Display String
-1 (disregard history) to 32
AtpcLevelSteps
710.3.3. 6.25.6
(*Atpc 6)
Applicable to IF based AU only. The
step size in percentages of
maximum number of available levels
that the SU will use when receiving
an ATPC Power-Up/Power-Down
message.
Integer
1-100(%)
na (255)
AtpcMaxLastLevelTimeAfterReset
710.3.3. 6.25.7
(*Atpc 7)
Applicable to IF based SU and SU-
R-3.5ab units only. The maximum
time (in seconds) of scanning
attempts after reset, using the last
value of
*CurrentTransmitPowerControl,
before returning to the configured
value of *TransmitPowerControl (IF-
based SU) or *CurrentTxPwrLvl (SU-
R-3.5ab).
Integer
0 to 3600 [Seconds]
AtpcMaxLastLevelTimeAfterSyncLoss
710.3.3. 6.25.8
(*Atpc 8)
Applicable to IF based SU and SU-
R-3.5ab units only. The maximum
time (in seconds) of scanning
attempts after synchronization loss,
using the last value of
*CurrentTransmitPowerControl,
before returning to the configured
value of *TransmitPowerControl (IF-
based SU) or
brzaccCurrentTxPwrLvl (SU-R-
3.5ab).
Integer
0 to 3600 [Seconds]
*ACSEParameters
710.3.3. 6.27
(*AirInterface 27)
Applicable for AU, SU and GU.
ACSE Voice Scheduler parameters.
MIB Parameter
(Location in Parenthesis)
Description Values/Range