Instruction manual

2-114
BreezeACCESS Version 4.3 Operations and Administration
Manual Revision: 4.0
Alarms In Names And Status
Displays the names and current status (ON or OFF) for all Alarm In
indications, including “internal” alarms, as follows:
Alarm In 1 through Alarm In 4: Name according to the name
defined in the Alarms In Names Menu.
Alarm In 5: GPS Antenna Status.
Alarm In 6: NA (reserved for future use).
Alarm In 7: PS1 Over Temperature (over temperature indication
for BS-PS Power Supply module 1, which is the module inserted
in the left-most slot of the chassis).
Alarm In 8: PS2 Over Temperature (over temperature indication
for BS-PS Power Supply module 2, which is the module inserted
in the right-most slot of the chassis).
Alarm In 9: PS1 Power (power fail indication for BS-PS Power
Supply module 1, which is the module inserted in the left-most
slot of the chassis).
Alarm In 10: PS2 Power (power fail indication for BS-PS Power
Supply module 2, which is the module inserted in the right-most
slot of the chassis).
Alarms Out Names, Definitions, Control and Status
Displays the following information for each of the three Alarms Out:
Name: Name according to the name defined in the Alarms In
Names Menu.
Definition: NONE, Alarm In # or ANY, according to the
configuration in the Automatic Alarms Out Definition Menu.
Control: OFF, ON or AUTO, according to the configuration in the
Alarms Out Control Menu.
Status: ON or OFF.
NOTE:
In some installations only one Power Supply module (either PS1 or PS2) may
be used.