Instruction manual
Menus and Parameters
2-105
BreezeACCESS Version 4.3 System Manual
Error Tone – Defines the tone transmitted to the earphone to
indicate that the system cannot currently support the call (e.g. if for
any reason the call was disconnected because of a problem in the
wireless link or incompatible capabilities) or if the user did not hang
up after exceeding the specified duration of the Dial, Ring Back,
Busy or Congestion Tones.
High Level Error Tone – Defines the high level tone transmitted to
the earphone to better attract the attention of the user if he did not
hang up after exceeding the specified duration of the Error Tone.
The various tones are defined by specifying the following
parameters:
Frequency 1 – One of two frequencies that can be used for
generating the applicable tone.
Valid values are 0-3000 (in Hz).
Frequency 2 – The second of the two frequencies to be used for
generating the applicable tone.
Valid values are 0-3000 (in Hz).
Level 1 – The level (in dBm) of Frequency 1.
Valid values are –32 to +3.
Level 2 – The level (in dBm) of Frequency 2.
Valid values are –32 to +3.
Cadence On – The ringing time (on) in the tones-silence
sequence of the tone.
Valid values are 100 – 10,000 milliseconds, 0 (0 means that
the tone is not used).
Cadence Off – The silence time (off) in the tones-silence
sequence of the tone.
Valid values are 100 – 10,000 milliseconds, 0 (0 means no
silence – a continuous tone).
Duration – The maximum duration of transmitting the tone to
the earphone. Tone generation will cease upon hang-up.
Valid values are 0 – 10,000 seconds.
Ring Frequency - Defines the ring frequency parameters (that
define the ringing of the telephone set), if the selected Telephony
Country parameter is Proprietary. The following parameters can be
defined:
Ringer Frequency – the frequency of activating the Ringer.
Valid values are: 17Hz, 20Hz, 25Hz, 50Hz.
Cadence On – The ringing time (on) in the ringing-silence
sequence of the Ringer.
Valid values are 100 – 10,000 milliseconds.