Menus and Parameters
2-33
BreezeACCESS Version 4.3 System Manual
The AU Alarms Menu
The AU Alarms menu enables to configure relevant parameters and to
view current statistics. The AU Alarms menu is available only with
Administrator access rights, except for Show All AU Alarms
Parameters and Data that is also available with Installer access rights.
AU Alarms Option - Enables to enable or disable the AU Alarms
feature. The default is Disable.
Learning Period - Enables to define the period dedicated to
accumulating information without generating alarms (except for the
No association alarm).
Valid values: 1 to 1440 (minutes)
Default: 30 (minutes)
Test Cycle - Enables to define the time between two consecutive
transmissions of a polling message and for calculating the current
averages for the various traffic statistics.
Valid values: 1 to 1440 (minutes)
Default: 10 (minutes)
Traffic Statistics - A sub menu that includes the following options:
Retransmissions Rate Parameters
Dropped Frames Rate Parameters
CRC Error Rate Parameters
Duplicate Frames Rate Parameters
For each of these traffic statistics types, a sub menu enables to
configure three parameters:
Minor Alarm Minimum Delta - The minimum difference
between the Current Rate and the previous Average Rate,
for activating a minor severity alarm, for the relevant
statistics type. Another prerequisite for activating the alarm
is that the relevant Current Rate exceeds the applicable
Minor Alarm Threshold.
Valid range: 0 to 100 (%)
Minor Alarm Threshold - The threshold for activating a
minor severity alarm for the relevant traffic statistics type.
Another prerequisite for activating the alarm is that the
difference between the applicable Current Rate and the
previous Average Rate exceeds the Minor Alarm Minimum
Delta.
Valid range: 1 to 100 (%)
Major Alarm Threshold - The threshold for activating a
major severity alarm for the relevant statistics type.
Valid range: 1 to 100 (%)