Instruction manual
Menus and Parameters
2-9
BreezeACCESS Version 4.3 System Manual
Set Complete Operator Defaults – Available only with
Administrator access rights. Set the unit to its’ Operator
Defaults configuration. After the next reset, all parameters
will revert to their Operator Defaults values, except for the
parameters that are marked in the “Complete” column of
Table 2-1‚ page 2-7
. Operator Defaults configuration can be
defined by the Administrator (see Save Current
Configuration As Operator Defaults below). It may also be
defined at the factory according to customer’s definition. The
default Operators Defaults configuration is the Factory
Defaults configuration.
The complete Operator Defaults Configuration file can be
downloaded/uploaded using TFTP with the SNMP Write
community string. The procedure is the same as for
downloading/uploading configuration files, except that
the extension used for the file name is .cmr.
Examples (using the default SNMP Write community
string):
To upload the configuration file using DOS based TFTP
Client to an SU whose IP address is 206.25.63.65:
tftp 206.25.63.65 put Suconf private.cmr.
To download the configuration file from the same unit:
tftp 206.25.63.65 get private.cmr Suconf
Set Partial Operator Defaults – Reverts all parameters to the
values of the Operator Defaults configuration after the next
reset, except for parameters that are necessary to maintain
connectivity and to enable management of the unit and some
other sensitive parameters. The exact list of parameters that are
not changed depends on the access rights of the user.
Referring to Table 2-1‚ page 2-7
, the parameters that are not
changed after activating Set Partial Operation Defaults using
Administrator access rights are marked in the “Partial-Admin”
Column. The parameters that are not changed after activating
Set Partial Operator Defaults using Installer access rights are
marked in the “Partial-Installer” Column.
Save Current Configuration As Operator Defaults – Defines
the current configuration of the unit as the Operator Defaults
configuration. This option is only available with Administrator
access rights.
Change Unit Name – Changes the name of the unit, which is also
the system name in MIB2. This name is also used as the prompt of
the monitor program menus.
Valid values: A string of up to 32 printable ASCII characters.
NOTE:
Activating Set Complete Operator Defaults will result in loss of connectivity.
If the unit is managed remotely, you may lose the ability to communicate with it.