Instruction manual

3-8
BreezeACCESS Version 4.5 System Description
Manual Revision: 1.0
AU-A/E-NI Stand-Alone Access Unit
Connectors
Electrical
Mechanical
Unit Connector Description
AU-NI IF TNC jack, 50 ohm, lightning protected
ETH 10BaseT Ethernet (RJ 45) with 2 embedded LEDs
Cable connection to a PC: crossed
DC-12 V DC phone jack for the AU-PS power supply
MON RS 232, 3-pin low profile jack
AU-RE IF TNC jack, 50 ohm, lightning protected
ANT N-Type jack, 50 ohm, lightning protected
AU-RA IF TNC jack, 50 ohm, lightning protected
Unit Details
General Power consumption: 25 W
AU-NI External power supply
AC input power: 100-240 Vr.m.s., 47-63 Hz
DC power output: 12 V, 4 A
AU-RA/AU-RE 12 VDC from the AU-NI unit over the IF cable
Unit Structure Dimensions Weight
General An indoor AU-NI unit with an external AU-PS
power supply unit and an outdoor AU-RE radio
unit
AU-NI Metal box, desktop or wall mountable 15 x 8.7 x 3.7 cm 0.34 kg
AU-PS Desktop unit, 1.5 m DC cable 12 x 6 x 3.6 cm 0.28 kg
AU-RE Metal box, poll or wall mountable 30.6 x 12 x 4.7 cm 1.58 kg
AU-RA Metal box plus an integral antenna, poll or wall
mountable
72.5 x 13 x 6.2 cm
(30.6 x 12 x 4.7 cm
+ 72.5 x 13 x 1.5
cm)
2.8 kg