Instruction manual
Specifications
3-5
BreezeACCESS Version 4.5 System Manual
Configuration and Management
GU-RA GPS Radio
GU-RA to BS-GU Communication
Maximum IF Cable Attenuation 15 dB
Maximum IF Cable DC Resistance 1.5 ohm
Parameter Value
Management Options a. Via the MON port, using terminal emulation with the built-in
monitor program
b. Telnet, using the monitor program
c. TFTP, using the Configuration upload/download utility
d. SNMP
Remote Management Access From Wired LAN, Wireless Link
Management Access
Protection
a. Multilevel password
b. Configuration of remote access direction (from Ethernet only,
from wireless link only or from both sides)
c. Configuration of IP addresses of authorized stations
SNMP Agents SNMP ver 1 client.
MIB II, Bridge MIB, Private BreezeACCESS MIB
Security a. Association protocol – ESSID
b. RC4 WEP option (encryption of the authentication process)
c. VLAN according to IEEE 802.1Q
d. IP level filtering for user addresses or protocols
e. Access direction and IP address filtering for management
Authentication and
Accounting
RADIUS client in the SU according to RFC 2865 and 2866
Allocation of IP Parameters Configurable or automatic (DHCP client)
Software Upgrade Via TFTP
Parameter Value
General L1 frequency, C/A code (SPS) continuous tracking receiver
Update Rate 1 Hz
Parameter Value
Physical interface RS 422
Cable Type EIA RS 422 3 x 2 x 26AWG + 1 x 2 x 24 AWG FTP Shielded.
3 x 26 AWG twisted pairs for RS 422 communication and 1x 24 AWG
pair for power supply
Parameter Value