Instruction manual
F-10
BreezeACCESS Version 4.5 System Manual
Manual Revision: 1.0
Hopping Standards: Korea
Each hopping sequence is comprised of 23 channels in the frequency band
from 2430 MHz to 2452 MHz (channels 30 to 52)
Calculating the operational hopping sequence:
Step Size D is defined as D(H, S) = 6 + (S-1) x 3 + (H-1)
Where:
S=Hopping Set. Range: 1-3
H=hopping Sequence. Range: 1-4
D(H, S) = Step Size for Hopping Set H and Hopping Sequence S.
Channel calculation:
P
i
(H, S) = [(i-1) x D (H, S)]
modulu23
+ 30
P
i
(H, S) = Channel with index i in operational sequence with Hopping Set S and
Hopping sequence H.
I = index. Range: 1-23
Example: H=1, S=3
Step Size Calculation: D (1, 3) = 6 + (3-1) x 3 + (1-1) = 12
Hopping sequence channels calculation:
P
1
(1, 3) = [(1-1) x 12]
mod23
+ 30 = 0
mod23
+ 30 = 0 + 30 = 30
P
2
(1, 3) = [(2-1) x 12]
mod23
+ 30 = 12
mod23
+ 30 = 12 + 30 = 42
P
3
(1, 3) = [(3-1) x 12]
mod23
+ 30 = 24
mod23
+ 30 = 1 + 30 = 31
P
4
(1, 3) = [(4-1) x 12]
mod23
+ 30 = 36
mod23
+ 30 = 13 + 30 = 43
P
5
(1, 3) = [(5-1) x 12]
mod23
+ 30 = 48
mod23
+ 30 = 2 + 30 = 32
P
6
(1, 3) = [(6-1) x 12]
mod23
+ 30 = 60
mod23
+ 30 = 14 + 30 = 44
P
7
(1, 3) = [(7-1) x 12]
mod23
+ 30 = 72
mod23
+ 30 = 3 + 30 = 33
P
8
(1, 3) = [(8-1) x 12]
mod23
+ 30 = 84
mod23
+ 30 = 15 + 30 = 45
P
9
(1, 3) = [(9-1) x 12]
mod23
+ 30 = 96
mod23
+ 30 = 4 + 30 = 34
P
10
(1, 3) = [(10-1) x 12]
mod23
+ 30 = 108
mod23
+ 30 = 16 + 30 = 46
P
11
(1, 3) = [(11-1) x 12]
mod23
+ 30 = 120
mod23
+ 30 = 5 + 30 = 35
P
12
(1, 3) = [(12-1) x 12]
mod23
+ 30 = 132
mod23
+ 30 = 17 + 30 = 47
P
13
(1, 3) = [(13-1) x 12]
mod23
+ 30 = 144
mod23
+ 30 = 6 + 30 = 36
P
14
(1, 3) = [(14-1) x 12]
mod23
+ 30 = 156
mod23
+ 30 = 18 + 30 = 48
P
15
(1, 3) = [(15-1) x 12]
mod23
+ 30 = 168
mod23
+ 30 = 7 + 30 = 37
P
16
(1, 3) = [(16-1) x 12]
mod23
+ 30 = 180
mod23
+ 30 = 19 + 30 = 49