Instruction manual

F-8
BreezeACCESS Version 4.5 System Manual
Manual Revision: 1.0
Hopping Standards: Japan
Each hopping sequence is comprised of 23 channels in the frequency band
from 2473 MHz to 2495 MHz (channels 73 to 95).
Calculating the operational hopping sequence:
Step Size D is defined as D(H, S) = 6 + (S-1) x 3 + (H-1)
Where:
S=Hopping Set. Range: 1-3
H=hopping Sequence. Range: 1-4
D(H, S) = Step Size for Hopping Set H and Hopping Sequence S.
Channel calculation:
P
i
(H, S) = [(i-1) x D (H, S)]
modulu23
+ 73
P
i
(H, S) = Channel with index i in operational sequence with Hopping Set S and
Hopping sequence H.
I = index. Range: 1-23
Example: H=1, S=3
Step Size Calculation: D (1, 3) = 6 + (3-1) x 3 + (1-1) = 12
Hopping sequence channels calculation:
P
1
(1, 3) = [(1-1) x 12]
mod23
+ 73 = 0
mod23
+ 73 = 0 + 73 = 73
P
2
(1, 3) = [(2-1) x 12]
mod23
+ 73 = 12
mod23
+ 73 = 12 + 73 = 85
P
3
(1, 3) = [(3-1) x 12]
mod23
+ 73 = 24
mod23
+ 73 = 1 + 73 = 74
P
4
(1, 3) = [(4-1) x 12]
mod23
+ 73 = 36
mod23
+ 73 = 13 + 73 = 86
P
5
(1, 3) = [(5-1) x 12]
mod23
+ 73 = 48
mod23
+ 73 = 2 + 73 = 75
P
6
(1, 3) = [(6-1) x 12]
mod23
+ 73 = 60
mod23
+ 73 = 14 + 73 = 87
P
7
(1, 3) = [(7-1) x 12]
mod23
+ 73 = 72
mod23
+ 73 = 3 + 73 = 76
P
8
(1, 3) = [(8-1) x 12]
mod23
+ 73 = 84
mod23
+ 73 = 15 + 73 = 88
P
9
(1, 3) = [(9-1) x 12]
mod23
+ 73 = 96
mod23
+ 73 = 4 + 73 = 77
P
10
(1, 3) = [(10-1) x 12]
mod23
+ 73 = 108
mod23
+ 73 = 16 + 73 = 89
P
11
(1, 3) = [(11-1) x 12]
mod23
+ 73 = 120
mod23
+ 73 = 5 + 73 = 78
P
12
(1, 3) = [(12-1) x 12]
mod23
+ 73 = 132
mod23
+ 73 = 17 + 73 = 90
P
13
(1, 3) = [(13-1) x 12]
mod23
+ 73 = 144
mod23
+ 73 = 6 + 73 = 79
P
14
(1, 3) = [(14-1) x 12]
mod23
+ 73 = 156
mod23
+ 73 = 18 + 73 = 91
P
15
(1, 3) = [(15-1) x 12]
mod23
+ 73 = 168
mod23
+ 73 = 7 + 73 = 80
P
16
(1, 3) = [(16-1) x 12]
mod23
+ 73 = 180
mod23
+ 73 = 19 + 73 = 92