Instruction manual
F-6
BreezeACCESS Version 4.5 System Manual
Manual Revision: 1.0
Hopping Standards: France
Each hopping sequence is comprised of 35 channels in the frequency band
from 2448 MHz to 2482 MHz (channels 28 to 82).
Basic Hopping Sequence: Hopping Set=1, Hopping Sequence = 1
Actual Frequency: (2400+Channel)MHz
Calculating the operational hopping sequence:
IF [P
i
(1, 1)+(S-1)x3+(H-1)]>82, than P
i
(H, S) = P
i
(1, 1)+(S-1)x3+(H-1)-35,
else P
i
(H, S) = P
i
(1, 1)+(S-1)x3+(H-1), where:
S=Hopping Set. Range: 1-3
H=hopping Sequence. Range: 1-11
i =Index. Range: 1-35
P
i
(H, S) = Channel with index i in operational sequence with Hopping Set S and
Hopping sequence H.
P
i
(1, 1) = Channel with index i in the basic sequence (Hopping Set 1, Hopping
sequence 1).
Index Channel Index Channel
165 19 76
253 20 62
366 21 73
480 22 48
571 23 56
655 24 49
764 25 63
852 26 51
961 27 59
10 81 28 78
11 74 29 72
12 58 30 57
13 79 31 75
14 68 32 67
15 77 33 50
16 70 34 69
17 60 35 82
18 54