Instruction manual
F-2
BreezeACCESS Version 4.5 System Manual
Manual Revision: 1.0
Actual Frequency: (2400+Channel) MHz
Calculating the operational hopping sequence:
IF [P
i
(1, 1)+(S-1)x3+(H-1)]>61, than P
i
(H, S) = P
i
(1, 1)+(S-1)x3+(H-1)-60,
else P
i
(H, S) = P
i
(1, 1)+(S-1)x3+(H-1)
Where:
S=Hopping Set. Range: 1-3
H=hopping Sequence. Range: 1-20
i =Index. Range: 1-60
P
i
(H, S) = Channel with index i in operational sequence with Hopping Set S and
Hopping sequence H.
P
i
(1, 1) = Channel with index i in the basic sequence (Hopping Set 1, Hopping
sequence 1).