6. To verify the connection, ping the unit’s IP address. Verify that ping
replies are being received.
The procedure to be used depends on the unit’s FLASH memory type.
Identify the FLASH memory type by using the monitor program,
connecting the PC to the unit either directly or via Telnet.
From the Main Menu, select 1 – Info Screens. From the Info Screen
menu select 1 – Show Unit Status. The last line of the Unit Status
display will indicate the FLASH type (type F or type S).
Use the TFTP utility, with the following syntax, to perform the upgrade:
tftp –i hostaddress put sourcefile [destinationfile]
Where -i is for binary mode, hostaddress is the IP address of the
unit to be upgraded, put defines that the PC (client) will send a file to
the hostaddress and destinationfile is the name of the file to be
loaded.
Loading an Upgrade to a Unit
with FLASH Type: F
Use the following table to determine which source file name to use,
according to the unit’s type.
X, refers to the software version number, up to 5 decimal digits
(e.g. for software release 4.0.40, X=4040).
Use the SNMP write community <SnmpWriteCommunity>.dwn (the
default write community is private) to define the destination filename.
For example, to load the upgrade file A3011F.BS to an AU whose IP
address is 206.25.63.65 use the following syntax:
tftp –i 206.25.63.65 put A3011F.BS private.dwn
Unit Type Source File Name
AU AXF.BS
SU AXF.SU
SU with Voice AXF.SUV
GU AXF.GU