Instruction manual
2-124
BreezeACCESS Version 4.5 Operations and Administration
Manual Revision: 1.0
! Show Alarm Parameters.
Alarms In Names
The Alarms In Names menu allows names for each of the four external
alarm indications that can be connected to the AL IN connector to be
defined. These names can reflect the specific environment in which the
module is being used (e.g. “Smoke Detector 1” or “Main Door”).
Each Alarms In Name can contain up to 31 printable ASCII characters
(case sensitive).
The default names are Alarm In 1 through Alarm In 4.
Alarms Out Names
The Alarms Out Names menu allows names for each of the three
external devices that can be connected to the AL OUT connector to be
defined. These names can reflect the specific environment in which the
module is being used (e.g. “Alarm Light 1”).
Each Alarms Out Name can contain up to 31 printable ASCII characters
(case sensitive).
The default names are Alarm Out 1 through Alarm Out 3.
Automatic Alarms Out Definition
The Automatic Alarms Out Definition menu allows you to define the
conditions under which each of the 3 Alarms Outs is to be activated
(when operating in Automatic mode). The available options for each of
the three Alarms Out are:
! 1 – Activate if Alarm In 1 turns ON.
! 2 – Activate if Alarm In 2 turns ON.
! 3 – Activate if Alarm In 3 turns ON.
! 4 – Activate if Alarm In 4 turns ON.
! 5 - Activate if Alarm In 5 (GPS Antenna Status) turns ON
! 6 - Not Applicable (Alarm In 6 is not defined)
! 7 - Activate if Alarm In 7 (PS1Over Temperature) turns ON
! 8 - Activate if Alarm In 8 (PS2 Over Temperature) turns ON
! 9 - Activate if Alarm In 9 (PS1 Power) turns ON
! 10 - Activate if Alarm In 10 (PS2 Power) turns ON
! N – None (never activate this Alarm Out).
! A - Activate if ANY of the Alarms In turns ON.
The default for all three Alarms Out is 0 (None – never activate the
alarm).