Instruction manual

2-112
BreezeACCESS Version 4.5 Operations and Administration
Manual Revision: 1.0
" Min On-Hook Detect Time The minimum time for decision on
an on-hook condition.
Valid values: 210 – 2,000 milliseconds, in steps of 10 ms.
Must be higher than Max Flash Detect Time.
Default: country-specific
" Called Party Release Timeout – The minimum time for an
on-hook signal on the called party side to be considered as call
disconnect.
Valid values: 0 – 10,000 seconds
Default: country-specific
" Pulse Dialing Timoeouts: These parameters support definition
of pulse dialing parameters, including Make time, Break time,
dialing frequency (period) and Make to Break ratio. With these
parameters one can configure the pulse dialing parameters to be
in accordance with any National standard. A validation function
is being used when Pulse dialing parameters are defined. This
validation function basically checks if the parameter is in
specified range and if maximum values are higher than
minimum values. For On-Hook recognition time the validation
function checks also if it is greater than maximum flash time. If
not it will automatically assign to On-Hook recognition time
20ms more than maximum flash recognition.
# Min Break Time – The minimum break time when using
pulse dialing.
Range: 10 to 200 ms using steps of 10 ms.
Default: country specific.
# Max Break Time – The maximum break time when using
pulse dialing.
Range: 10 to 200 ms using steps of 10 ms.
Default: country specific.
# Min Period (Break+Make) Time – The minimum period
(break plus make) time when using pulse dialing.
Range: 40 to 200 ms using steps of 10 ms.
Default: country specific.
# Max Period (Break+Make) Time – The maximum period
(break plus make) time when using pulse dialing.
Range: 40 to 200 ms using steps of 10 ms.
Default: country specific.
# Min Make/Break Ratio – The minimum ratio of make to
break times when using pulse dialing.
Range: 30 to 330 (%).
Default: country specific.
# Max Make/Break Ratio – The maximum ratio of make to
break times when using pulse dialing.