Menus and Parameters
2-103
BreezeACCESS Version 4.5 System Manual
6 if ACSE Option is enabled. (covers all G729 codecs, including
G729Annex A, G729wAnnexB and G729AnnexAwAnnexB)
" G711u-law Frames Per Packet – Valid range is 1-16,
Default value is 12
" G711A-law Frames Per Packet – Valid range is 1-16,
Default value is 12
! Voice Activity Detection – Enables or disables the use of Voice
Activity Detection (VAD). When the VAD algorithm is enabled,
silence intervals are identified. Therefore, only relevant information
is transmitted, using less bandwidth than during voice activity
intervals. This allows for a better overall utilization of the available
bandwidth. Voice Activity Detection is not applicable when using the
G711 codec. Voice Activity Detection is implemented automatically
in G729wAnnexB and G729 Annex A w Annex B (Annex B activates
the silence compression).
Available options are:
" Voice Activity Detection OFF.
" Voice Activity Detection G7231 (enable when using G723.1
compression).
The default selection is Voice Activity Detection OFF.
! Input (A/D) Gain - Applicable only to SU with voice HW version D
and above. The gain of the Analog to Digital input relative to 0dBm0
point.
Available range: -29 to +2 (dB)
Default value: 0 dB
! Output (D/A) Gain - Applicable only to SU with voice HW version D
and above. The gain of the Digital to Analog output relative to
0dBm0 point.
Available range: -29 to +2 (dB)
Default value: 0 dB
NOTE:
When the ACSE Option is enabled, this parameter is not applicable and the default