Instruction manual

2-60
BreezeACCESS Version 4.5 Operations and Administration
Manual Revision: 1.0
Table 2-9 -.: Transmit Power Output
New BreezeACCESS II AU-RA/RE-HP outdoor units, have an output
power control mechanism that is different from previous units.
The main differences are:
a. Higher Transmit Power Control dynamic range
b. The output power is not dependent on the attenuation of the IF
cable.
The new units can be distinguished from old units by the description
label on the unit that includes IC as a reference to Improved
Collocation: BreezeACCESS IC
The following table shows the new typical output power as a function of
the configured Transmit Power Control parameter.
Cable
attenuation
0dB 5dB 10dB 15dB
Transmit power
Control
Outdoor power
(dBm)
Outdoor power
(dBm)
Outdoor power
(dBm)
Outdoor power
(dBm)
15 24+/- 2 24+/- 2 24+/- 2 24+/- 2
14 24+/- 2 24+/- 2 24+/- 2 24+/- 2
13 24+/- 2 24+/- 2 24+/- 2 24+/- 2
12 23+/- 3 23+/- 3 23+/- 3 23+/- 3
11 23+/- 3 23+/- 3 23+/- 3 23+/- 3
10 23+/- 3 23+/- 3 23+/- 3 23+/- 3
9 23+/- 3 23+/- 3 22+/- 3 22+/- 3
8 23+/- 3 23+/- 3 22+/- 4 21+/- 4
7 22+/- 4 23+/- 3 21+/- 4 20+/- 4
6 22+/- 4 22+/- 4 20+/- 4 17+/- 4
5 22+/- 4 21+/- 4 19+/- 4 15+/- 4
4 21+/- 4 20+/- 4 18+/- 4 12+/- 4
3 21+/- 4 19+/- 4 16+/- 4 10+/- 4
2 20+/- 5 18+/- 5 14+/- 5 8+/- 5
1 19+/- 5 17+/- 5 13+/- 5 7+/- 5
0 18+/- 5 16+/- 5 11+/- 5 6+/- 5