Instruction manual
Menus and Parameters
2-35
BreezeACCESS Version 4.5 System Manual
The default parameters for these alarms is as follows:
"Show Traffic Statistics Parameters and Data - Displays for each
statistics type the configured parameters as well as the
applicable Current and Average Rates.
! SU Rx Power Test - A sub menu that includes the following
options:
" SU Rx Power Decrease Threshold - The minimum inverse
(negative) value of the SU Rx Power Average Delta that will
trigger an alarm.
Valid values: 1 to 99 (dB).
Default value: 15 (dB).
" Show SU Rx Power Test Parameters and Data - Displays the
value of the SU Rx Power Decrease Threshold and the current
SU Rx Power Average Delta.
! AU Rx Power Test - A sub menu that includes the following
options:
" AU Rx Power Decrease Threshold- The minimum inverse
(negative) value of the AU Rx Power Average Delta that will
trigger an alarm.
Valid values: 1 to 99 (dB).
Parameter Default (%)
Retransmission Minor Alarm Minimum Delta 20
Retransmission Minor Alarm Threshold 30
Retransmission Major Alarm Threshold 60
Dropped Frames Minor Alarm Minimum Delta 10
Dropped Frames Minor Alarm Threshold 10
Dropped Frames Major Alarm Threshold 20
CRC Error Minor Alarm Minimum Delta 20
CRC Error Minor Alarm Threshold 40
CRC Error Major Alarm Threshold 70
Duplicate Frames Minor Alarm Minimum Delta 5
Duplicate Frames Minor Alarm Threshold 5
Duplicate Frames Major Alarm Threshold 15
NOTE:
The value of the Major Alarm Threshold must be higher than the applicable
Minor Alarm Threshold. The system will not accept a Major Alarm Threshold
that is lower than the current Minor Alarm Threshold, and vice versa.