Instruction manual
1-2
BreezeACCESS Version 4.5 Operations and Administration
Manual Revision: 1.0
Accessing the Monitor
Program using the RS 232
MON Connector
1. Use the monitor cable to connect the MON connector of the unit to the COM
port of your ASCII ANSI terminal or PC. The COM port connector on the
monitor cable is a 9-pin D-type plug.
2. Run a terminal emulation program (such as HyperTerminal™).
3. Set the communication parameters to the following:
4. Press Enter. The Select Access Level menu appears. Select the access level
according to your authorized access level. You will be requested to enter
your password. After entering the correct password, press Enter.
Table 1-1‚ page 1-2 lists the default passwords for each of the access
levels.
Table 1-1: Default Passwords
NOTE:
The GU-BS GPS and Alarms module does not have an external MON port. It does have
an internal MON port that can be used in laboratory conditions (consult Alvarion
technical support for further details). It is recommended to use Telnet to access the
monitor program of the GU-BS.
Baud Rate 9600
Data Bits 8
Stop Bits 1
Parity None
Flow Control Xon/Xoff
Connector Connected COM port
Access Rights Password
Read Only public
Installer user
Administrator private
NOTE:
Following three unsuccessful login attempts (using incorrect passwords) from either the
monitor port or via Telnet, the monitor program will be blocked for five minutes. To
enable access to the monitor program during that time, the unit must be reset (via
SNMP or by disconnecting/reconnecting power).