Instruction manual
Setting Basic Parameters
1-7
BreezeACCESS Version 4.5 System Manual
Once the basic parameters are configured, the unit must be reset in
order to activate the new configuration.
Configuring Parameters in
GU-A-BS Units
Introduction
This section describes all the parameters that are necessary for the
initial installation and operation of GU-A-BS units. Once the unit is
properly installed and operational, other parameters can be configured
using the monitor program via Telnet or SNMP management.
Since all the parameters needed are found in the Advanced
Configuration menu, Administrator level access is required in order to
configure a GU-A-BS unit.
Refer to Book 4: Operation and Administration for detailed information
on the applicable parameters.
In many installations, most of these parameters should not be changed
from their default values. The following list includes the basic
parameters and their default values:
Table 1-6: GU-A-BS Units Basic Parameters
Authentication Algorithm Open System In the SU, can be changed to
Shared Key only after
configuring the WEP Key and
the applicable Default Key ID.
In the AU at least one WEP key
must be configured.
Default Key ID (SU) 1
WEP Key 1-4 0000000000 (none)
Encryption Seed 7
Encryption Polynom Index 0
NOTE:
The BS-GU does not have an external MON port, and therefore must be configured
using Telnet.
Table 1-4: Subscriber and Access Units Basic Parameters
Parameter Default Value Comment