Chapter 2 - Managing a Single Device/Cell Air Interface Interference Mitigation Parameters Page
AlvariCRAFT Device Manager 67 User Manual
2.7.4 Output Parameters
The Output Parameters table is populated with specific scanning parameters for
each channel:
After scanning the spectrum and analyzing the results, the unit will suggest the
optimal configuration for the setup:
Scanning Period (min) Duration (in minutes) of the scanning. The unit may stop recording
prematurely when a limit of 100 000 events is reached.
Channel Scan Period
(sec)
The period of time, in seconds, to stay on each channel to gather
information. The unit may stop recording prematurely when a limit of
100 000 events is reached.
Range: 2 - 30 seconds
Channel Frequency in MHz
Scan Type Scanning type:
1 - For Clear Channel & Automatic Noise Floor Selection
2 - For Automatic Noise Floor Selection Only
3 - For Clear Channel Selection Only
4 - For Statistics Only
Installation Model Type of instalation:
1 - For Line Of Sight setups
2 - For Near Line Of Sight setups
3 - For No Line OF Sight setups
Noise floor Channel detected noise floor
Distance Requested Maximum Distance (in meters)
Performance Requestet Throughput (in Kbps)
Operating Channel The operating channel suggested by the unit based on the
Interference Mitigation analysis
Noise Floor The noise floor suggested by the unit based on the Interference
Mitigation analysis