User manual
Chapter 2 - Managing a Single Device/Cell Air Interface General Page
AlvariCRAFT Device Manager 41 User Manual
meaning that SU/RB is not associated, and the reason of rejection - wrong
ESSID.
An SU/RB that is trying to associate with AUs/BUs that are working with Hidden
ESSID will keep a list with AUs/BUs that rejected. The AU/BU will be kept in this
list until the Hidden ESSID Time-out expires for it or if the list is full and another
AU/BU that is not in the list rejects the SU/RB because of wrong ESSID.
The AU/BU that is working with Hidden ESSID enable will keep a counter that
will be incremental for each SU/RB that is rejected because of wrong ESSID.
The Operator ESSID feature still works when Hidden ESSID is enabled. The only
differences is that the Runtime ESSID displayed by SU/RB, when the SU/RB is
associated because of Operator ESSID, will be the ESSID of the SU/RB and not
the ESSID of the AU/BU as it is when Hidden ESSID is disabled.
The ESSID parameters includes the following:
ESSID The ESSID of the unit.
Valid values: A string of up to 31 printable ASCII characters, case
sensitive.
Operator ESSID Option Applicable only for AU and BU. The Operator ESSID Option enables
or disables the use of Operator ESSID for establishing association
with SUs/RB.
Operator ESSID Applicable only for AU and BU. The Operator ESSID.
Valid values: A string of up to 31 printable ASCII characters, case
sensitive.
Runtime ESSID Applicable only for SU and RB. Read-only display of the actual
ESSID used by the unit.
Hidden ESSID Option Applicable only for AU and BU. The Hidden ESSID Option enables or
disables the Hidden ESSID feature. When enabled, the ESSID will
not be broadcasted by the AU/BU.
Hidden ESSID Support Applicable only for SU and RB. The Hidden ESSID Support option
enables or disables the Hidden ESSID feature in the SU/RB.
Hidden ESSID Timeout Applicable only for SU and RB. The Hidden ESSID Timeout
parameter defines the time that SU/RB will not try again to associate
with an AU/BU that is working with Hidden ESSID if the AU/BU
rejected Association Request sent by the SU/RB because of wrong
ESSID.
The range is from 1 to 60 minutes.