User manual
Chapter 2 - Managing a Single Device/Cell Bridging Page
AlvariCRAFT Device Manager 111 User Manual
Rule ID (Inside Extended
Access Table - SU only)
Defines the type of rule that is going to be applied:
No Rule - No rule is applied. Use this option to deactivate a rule
that is currently in use.
Source MAC Address - The rule will be applied on frames
with matching source MAC addresses.
Destination MAC Address - The rule will be applied on
frames with matching destination MAC addresses.
Source IP Address - The rule will be applied on frames with
matching source IP addresses.
Destination IP Address - The rule will be applied on frames
with matching destination IP address.
Source UDP Port - The rule will be applied on UDP frames
with matching source UDP ports.
Destination UDP Port - The rule will be applied on UDP
frames with matching destination UDP ports.
Source TCP Port - The rule will be applied on TCP frames
with matching source TCP ports.
Destination TCP Port - The rule will be applied on TCP
frames with matching destination TCP ports.
IP Protocol - The rule will be applied on frames with matching
IP protocols.
Default - This rule will be applied on frames that don’t match
any of the remaining rules.
By default, each rule is populated with the
No Rule setting.
When a frame matches multiple rule types, the rule type that is
highest in the list above (except for the No Rule type) will have
precedence and any other matching rule will be ignored. For instance,
a Source MAC Address rule will have precedence over a Destination
MAC Address rule, which in turn will have precedence over a srcIp
rule, etc.
If there are multiple rules of the same type, the lower the rule number,
the higher the precedence. For instance, Rule 1 will have precedence
over Rule 2, which will have precedence over Rule 3, if rules 1, 2 and
3 have the same type.