Frames From wireless The total number of frames received from the wireless link. The count
includes data frames as well as control and wireless management
frames. The count does not include bad frames and duplicate frames.
Bad Fragments The number of fragments received from the wireless link containing
CRC errors.
Duplicate Frames
Discarded
The number of data frames discarded because multiple copies were
received. If an acknowledgement message is not received by the
originating unit, the same data frame can be received more than
once. Although duplicate frames are included in all counters that
include data frames, only the first copy is forwarded to the Ethernet
port.
Data Frames The total number of data frames received from the wireless link,
including duplicate frames.
Phy The total number of frames that were not received properly due to
Phy errors (unidentified signals).
CRC The number of frames received from the wireless medium containing
CRC errors.