Specifications
Chapter 2 - Installation Installing the Outdoor Unit
BreezeACCESS 4900 36 System Manual
1 Attach the Tilt accessory to the ODU using the two pairs of flat washers, spring
washers and nuts supplied in the Tilt kit.
1 Mount the Tilt accessory on a 1" to 4" pole using two 9/16" metal bands.
1 Release slightly the Tilt Control Screw, tilt the ODU downward/upward as
required, and re-tighten the screw.
2.3.2 Protecting ODU Connections
Use appropriate sealing material to protect the connection against moisture and
humidity. Use removable sealing material, such as a tar seal, to enable future
access to the connector.
Loop and tie the cable near the unit for strain relief and for routing water away
from the unit: use additional cable strips to route the cable such that water can
accumulate on the cable bends, away from the unit.
2.3.3 Connecting the Grounding and Antenna
Cables
The Grounding screw (marked ) is located on the bottom panel of the outdoor
unit. The Antenna RF connector (marked ) is located on the top panel of the
AU-ODU.
1 Connect one end of a grounding cable to the grounding terminal and tighten
the grounding screw firmly.
2 Connect the other end of the grounding cable to a good ground (earth)
connection
1 Connect one end of the coaxial RF cable to the RF connector on the unit.
NOTE
Use high quality sealing material such as Scotch
®
130C Linerless Rubber Splicing Tape from 3M to
ensure protection against dust and water.
To connect the grounding cable:
To connect the RF cable (units with external antenna):