Specifications

Chapter 2 - Installation Installation Requirements
BreezeACCESS 4900 29 System Manual
A Y-cable for connecting directly to the IDU COM of ODUs with a new (smaller
size) enclosure for configuration/performance monitoring using a portable PC.
2.1.1.5 Additional Installation Requirements
The following items are also required to install the BreezeACCESS 4900 system
components:
Indoor-to-outdoor Category 5E Ethernet cable with shielded RJ-45 connectors
* (available in different lengths. For more details refer to Section 2.1.2)
Ethernet cable (straight for connecting to a hub/switch etc., crossed for
connecting directly to a PC's NIC)
Crimping tool for RJ-45 connectors
Antenna (for E model units supplied without an antenna) and RF cable.
Ground cables with an appropriate termination
Mains plug adapter or termination plug (if the power plug on the supplied AC
power cord does not fit local power outlets)
Portable PC with Ethernet card and Telnet software or AlvariCRAFT for
BreezeACCESS 4900* application and a crossed Ethernet cable
Installation tools and materials, including appropriate means (e.g. a pole) for
installing the outdoor unit.
2.1.2 Indoor-to-Outdoor Cables
NOTE
Items marked with an asterisk (*) are available from Alvarion.
NOTE
The length of the indoor-to-outdoor Ethernet cable should not exceed 90 meters. The length of the
Ethernet cable connecting the indoor unit to the user's equipment, together with the length of the
Indoor-to-Outdoor cable, should not exceed 100 meters.