Specifications
Chapter 4 - Operation and Administration Menus and Parameters
BreezeACCESS 4900 150 System Manual
4.2.6.4.1.4 VLAN Forwarding (AU and SU)
The VLAN Forwarding feature is applicable only for Trunk Links, Service Provider
Links and Extended Trunk Links (SU only). It enables defining the VLAN ID values
to be included in the VLAN Forwarding List. If the Link Type is defined as either a
Trunk Link, a Service Provider Link or an Extended Trunk Link (SU only) and the
VLAN Forwarding option is enabled, a data frame received with a VLAN ID (or a
Service Provider VLAN ID) that is not a member of the unit's VLAN Forwarding List
is discarded.
The VLAN Forwarding submenu provides the following options:
4.2.6.4.1.4.1 VLAN Forwarding Support
The VLAN Forwarding Support option enables or disables the VLAN Forwarding
feature.
Available selections are Disable and Enable.
The default selection is Disable.
4.2.6.4.1.4.2 Add Forwarding VLAN ID
The Add Forwarding VLAN ID option enables adding a VLAN ID to the VLAN
Forwarding List. One VLAN ID can be entered at a time. The maximum number of
VLAN IDs in the VLAN Forwarding List is 20.
Valid values are 1 to 4094.
4.2.6.4.1.4.3 Remove Forwarding VLAN ID
The Remove Forwarding VLAN ID option enables removing a VLAN ID from the
VLAN ID Forwarding List.
Valid values are VID values (from 1 to 4094) that are included in the VLAN
Forwarding List.
4.2.6.4.1.4.4 Show VLAN ID Forwarding List
The Show VLAN Forwarding List option displays the values of the VLAN IDs
included in the VLAN Forwarding List.
Table 4-13: Extended Trunk Frame Routing
Incoming Frame Type Wireless to Ethernet Traffic Ethernet to Wireless Traffic
Untagged Drop Pass with native VLAN ID
Tagged with native VLAN ID Pass as untagged Drop
Tagged with other VLAN ID Pass Pass