Specifications
Chapter 4 - Operation and Administration Menus and Parameters
BreezeACCESS 4900 137 System Manual
Last Field Calibration Result: Indicating the result of the last Field
calibration process (Passed, Failed or None if no Field calibration has been
done).
Bandwidth Used for Last Field Calibration: The bandwidth used by the
device during the last Field Calibration. A new Field Calibration should be
performed after changing the bandwidth (sub-band) used by the device.
Available Calibration Options: Indicating whether Field, Factory or both
Field and Factory Calibration options are available for selection.
Selected Calibration Option: The currently selected Calibration Option to
Use.
4.2.6.3 Network Management Parameters
The Network Management Parameters menu enables protecting the Unit from
unauthorized access by defining a set of discrete IP addresses as well as IP
address ranges from which the unit can be managed using protocols such as
Telnet, FTP, TFTP, SNMP, DHCP and ICMP. This excludes management messages
generated in the unit, such as Traps or Ping Test frames, which are not filtered.
The direction from which management access is permitted can also be configured,
which means that management access may be permitted from the wireless
medium only, from the wired Ethernet only, or from both.
The Network Management Menu also enables managing transmission of traps,
including definition of up to 10 traps destination IP addresses and the associated
community strings. In addition, the menu enables specifying the IP address of a
connected AP client device to facilitate remote management of a BreezeACCESS
WI
2
system.
The Network Management Parameters menu includes the following options:
Access to Network Management
Network Management Filtering
Set Network Management IP address
Delete a Network Management IP Address
Delete All Network Management IP Addresses