Specifications

Chapter 4 - Operation and Administration Menus and Parameters
BreezeACCESS 4900 131 System Manual
Noise Floor Avg: The average Noise Floor (in dBm) calculated for the channel.
Noise Floor Max: The maximum Noise Floor (in dBm) calculated for the
channel.
4.2.6.2.13.7 Spectrum Analysis Information Display - Continuous
The Spectrum Analysis Information Display - Continuous option is available only
when the analysis process is active. It enables viewing the continuously updated
results of the current analysis process. The displayed information includes the
same details available for a regular Spectrum Analysis Information Display
option.
4.2.6.2.13.8 Show Spectrum analysis Parameters & Data
The Show Spectrum analysis Parameters & Data option enables viewing the
Spectrum analysis test parameters and the last test results.
4.2.6.2.14 Lost Beacons Transmission Watchdog Threshold (AU only)
When it is unable to send beacon frames for a predetermined period of time, such
as in the case of interferences, the AU resets itself. The Lost Beacons
Transmission Threshold parameter represents the number of consecutive lost
beacons after which the unit will reset itself.
The range for this parameter is 100 - 1000 or 0. When the parameter is set to 0,
this feature is disabled, i.e. internal refresh will never be performed.
The default value is 218.
4.2.6.2.15 Disassociate (AU only)
The Disassociate feature enables disassociating all SUs associated with the AU or
a selected SU. This feature is useful during configuration changes, enabling to
force the SU(s) to re-initiate the association process, including the search for the
best AU (or a preferred AU) using the Best AU process, without performing a full
reset.
The Disassociate submenu includes two options:
Disassociate All SUs
Disassociate SU By MAC Address: to disassociate a selected SU
4.2.6.2.16 Noise Immunity Control
Noise Immunity Control parameters are available only in units with HW Revision
C and higher, except to the Pulse Detection Sensitivity parameter that is available
also in units with HW Revision B.