Specifications
Chapter 4 - Operation and Administration Menus and Parameters
BreezeACCESS 4900 113 System Manual
Hidden ESSID Timeout expires for it or if the list is full and another AU that is not
in the list rejects the SU because of wrong ESSID.
The AU that is working with Hidden ESSID enable will keep a counter that will be
incremented for each SU that is rejected because of wrong ESSID.
The Operator ESSID feature still works when Hidden ESSID is enabled. The only
differences is that the Runtime ESSID displayed by SU, when the SU is associated
because of Operator ESSID, will be the ESSID of the SU and not the ESSID of the
AU as it is when Hidden ESSID is disabled.
The ESSID related parameters are:
4.2.6.2.1.1 ESSID
The ESSID parameter defines the ESSID of the unit.
Valid values: A string of up to 31 printable ASCII characters.
The default value is ESSID1.
4.2.6.2.1.2 Operator ESSID Parameters (AU only)
The Operator ESSID Parameters submenu includes the following parameters:
4.2.6.2.1.2.1 Operator ESSID Option
The Operator ESSID Option enables or disables the use of Operator ESSID for
establishing association with SUs.
The default is Enable.
4.2.6.2.1.2.2 Operator ESSID
The Operator ESSID parameter defines the Operator ESSID.
Valid values: A string of up to 31 printable ASCII characters.
The default value is ESSID1.
NOTE
The ESSID string is case sensitive.
NOTE
The Operator ESSID string is case sensitive.