Specifications

Chapter 4 - Operation and Administration Menus and Parameters
BreezeACCESS 4900 88 System Manual
average modulation. See “Threshold Mode Settings (SU only)” on page 88 for
details on how to set it up.
4.2.3.13.2 Threshold Mode Settings (SU only)
This submenu allows users to define the behavior for each LED in the SNR bar
when the Threshold Mode is employed.
4.2.3.13.2.1 LED 1 to 8
Selects the LED you wish to configure. You can define a threshold that must be
reached for the LED to light up by using the menus described below.
4.2.3.13.2.1.1Threshold Type
This option defines the parameter that is monitored and that the threshold is set
for:
Disabled: There is no threshold defined for the LED. The LED is always off,
unless all threshold conditions that were defined for the remaining LEDs are
met.
RSSI: Sets up a threshold for the Received Signal Strength Indication
CRC %: Sets up a threshold for the Cyclical Redundancy Check percentage.
SNR: Sets up a threshold for the Signal-to-Noise Ratio.
Average Modulation: Sets up a threshold for the average modulation.
4.2.3.13.2.1.2Threshold Mode
This option defines how the threshold parameter (see “Threshold Type” on
page 88) relates to the threshold target value (see “Threshold Target” on page 89).
The available operators are:
Equal or lower than: The threshold parameter must be lower than or equal to
the threshold target value for the LED to light up.
Equal or higher than: The threshold parameter must be higher than or equal
to the threshold target value for the LED to light up.
Equal to: The threshold parameter must be equal to the threshold target value
for the LED to light up.