SU Waiting Option: The SU Waiting Option defines whether the
disassociation message sent by the AU after detecting radar activity on the
current frequency will include a message instructing the SU to search only for
that specific AU before attempting to search for another AU. The message
includes also the time period during which the SU should not search for any
other AU. The waiting time is the Channel Check Time plus 5 seconds.
Clear DFS Channels Table: When enabled, than after the next reset all viable
frequencies will be marked in the database as Radar Free, including
frequencies previously marked as either Radar Detected or Adjacent to Radar.
In addition, the AU will start operation using its default frequency.
Minimum Pulses to Detect Radar: The minimum number of detected radar
pulses before reaching a decision that an active radar is using the channel.
The range is from 1 to 100 pulses.
Channel Reuse Option: Enabling/disabling the Channel Reuse algorithm.
Radar Activity Assessment Period: The period in hours used for assessment
of radar activity in the original channel.
The range is 1 to 12 hours.
Maximum Number of Detections in Assessment Period: The maximum
number of radar detection in the original channel during the Radar Activity
Assessment Period that is required for reaching a decision to try again the
original channel.
The range is 1 to 10 radar detections.
DFS Channels Table: Displays all the applicable frequencies together with
their status in the database (Radar Free, Radar Detected or Adjacent to
Radar).