User manual

Unit Configuration
BreezeCONFIG for BreezeACCESS VL and BreezeACCES 4900 User Manual
54
Automatic Channel Selection (AU only): The Automatic Channel selection
option defines weather the AU will choose the best noise free channel upon
startup after completion of the spectrum analysis process. The selection is per
analysis: once the analysis is completed it will be disabled automatically.
Current Status: A read-only display of the current status of the spectrum
analysis test.
Activate Spectrum Analysis: Click on the Activate Spectrum Analysis button
to activate the spectrum analysis process. Upon activation, the unit will reset
automatically and start-up in spectrum analysis mode.
Reset Counters: Click on the Rest Counters button to clear the spectrum
analysis counters.
Spectrum Analysis Table: The Spectrum Analysis Table displays the results
of the last analysis process. The displayed information includes the following
details for each channel:
Frequency in MHz
Signal Count: The number of signals (excluding OFDM frames with the
correct bandwidth) in the channel.
Signal SNR: The approximate SNR of signals (excluding OFDM frames
with the correct bandwidth) in the channel.
Signal Width: The average width in microseconds of signals (excluding
OFDM frames with the correct bandwidth) in the channel.
OFDM Count: The number of OFDM frames with the correct bandwidth
detected in the channel.