User manual

Unit Configuration
BreezeCONFIG for BreezeACCESS VL and BreezeACCES 4900 User Manual
46
The Frequency tab is comprised of the following components:
2.4.2.1 Current Frequency Definition
Current Operating Frequency: A read-only field that displays the current
operating frequency in MHz.
Current Bandwidth: A read-only field that displays the current bandwidth in
MHz.
Defined Frequency (AU only): The fixed operating frequency in MHz to be
used if the DFS option is disabled. This is also the first frequency to be used
by the DFS mechanism the first time it starts functioning. The available
values depend on the selected Sub-Band.
2.4.2.2 Planned Frequency Definition
In AU: The Planned Frequency Definition table enables defining the frequencies
that will be used in the DFS mechanism (if applicable). The available frequencies
according to the Sub-Band selected in the Country Code tab (if more than one
Sub Band is available) are displayed. Clicking the Activity field of the desired
frequency entry opens the selection/de-selection drop-down menu. A ‘+’ indicates
a selected frequency, while a ‘-‘ denominates an unselected one. Check the Set
Selected Frequencies checkbox to use the selected frequencies as the subset to
become effective after the next reset.
In SU: The Planned Frequency Definition table enables defining for each of the
available Sub-Bands the frequencies that will be used by the SU when scanning
for an AU. For each available Sub-Band, the available frequencies are displayed.
Clicking the Activity field of the desired frequency entry opens the selection/de-
selection drop-down menu. A ‘+’ indicates a selected frequency, while a ‘-‘
denominates an unselected one. A change in frequencies takes effect without the
need to reset the unit.