RunTime ESSID (SU only): A read-only field that displays the ESSID
currently used by the selected SUnit to associate with an AU.
2.4.1.3 ATPC Parameters
ATPC Option: From the dropdown list, select whether to Enable or Disable
the Automatic Transmit Power Control algorithm.
Minimum SNR Level (AU only): The minimum desired level in dB of the
average SNR at the AU for each SU. This value reflects the lower limit of the
optimal reception level range. Available values range from 4 to 60 dB.
Delta From Minimum SNR Level (AU only): The Minimum SNR Level plus
the value of this parameter define the maximum desired level of the average
SNR at the AU. This value reflects the upper limit of the optimal reception
level range. Available values range from 4 to 20 dB.
Level Steps (AU only): The step size in dB that the SU will use when
receiving an ATPC Power-Up/Power-Down message. The available values
range from 1 to 20 dB.
Minimum Interval Between ATPC Messages (AU only): The minimum
permitted time, in seconds, between consecutive power-up/power-down
messages. Available values range from 1 to 3600 seconds.