Per SU Distance learning (AU only): Defines the mode in which SUs
calculate the Acknowledge (ACK) timeout: based on the maximum cell
distance or on the actual distance from the AU. When this feature is disabled,
all SUs in the cell use the maximum cell distance for the calculation of the
ACK timeout; when enabled, each SU uses instead its actual distance from
the AU.
NOTE
The Per SU Distance Learning feature is supported only when the Cell Distance Option is set to
Automatic.
Fairness Factor (AU only): The Fairness Factor enables to define the level of
fairness in providing services to different SU. When set to 100%, all SUs have
the same probability of getting services when competing for bandwidth. If set
to X%, then SUs located up to X% of the maximum distance from the AU will
have advantage in getting services over SUs located farther than this distance.
The range is 0 to 100 (%).
Most Distant Unit (AU only): The MAC Address of the unit which the
Automatic Cell Distance algorithm identified as being the farthest from the
AU.
Measured Max Cell Distance (AU only): The distance of the farthest SU
served by the AU, as measured by the Automatic Cell Distance mechanism.
2.4.1.2 ESSID Parameters
ESSID: The Extended Service Set ID for the selected unit. The ESSID
identifies the wireless network, which prevents the unintentional merging of
two collocated wireless networks, since an SU can only associate with an AU
that has the identical ESSID. The ESSID can be a string of up to 31 case-
sensitive printable ASCII characters.
Operator ESSID Option (AU only): From the dropdown list, select whether to
Enable or Disable the Operator ESSID Option. The Operator ESSID is a
secondary ESSID to be used when adding additional Subscriber Units to
existing deployments, where the primary ESSID may differ among neighboring
AUs. It is also used to support the Best AU feature.
Operator ESSID (AU only): The secondary Extended Service Set ID for the
selected Access Unit. The ESSID can be a string of up to 31 case-sensitive
printable ASCII characters.