window is displayed, enabling you to select a location for the file and to define
a file name.
Main Version: Shows the version defined as the Main Version. This is the
version that will be used after the next reset.
Click Reset Device to reset the selected unit and apply any modifications
made to the system parameters.
Shadow Version: Shows the version defined as the Shadow Version. Click
Reset and Boot from Shadow Version to activate the shadow software
version. The unit is reset and the shadow version becomes active.
Running Software Version: Shows the currently active version. Click Use
Current Version After Reset to define the currently active version as the
version to be defined as the Main Version and used after the next reset.
NOTE
To replace the Main version with the Shadow version, you must first click
Reset and Boot from Shadow Version and then click Use Current Version After Reset.
Exit Telnet: Click Exit to log off from the current Telnet session.
Telnet Logout Timer: Click the up and down arrows or enter a number to
define the number of minutes that the Monitor program can remain inactive
before the unit automatically exits from the program. The time-out value can
range from 1 to 999 minutes.