User manual
Unit Configuration
BreezeCONFIG for BreezeACCESS VL and BreezeACCES 4900 User Manual
24
2.1 Unit Control Parameters
The Unit Control tab enables you to reset the unit and manage the software
versions in the selected unit(s), as shown below.
Figure 2-1: Unit Control Parameters (AU)
The Unit Control tab is comprised of the following components:
Unit Type: Displays the unit's functionality.
Unit Name: Displays the name of the selected device, which can be modified
in the Unit Status & Info tab.
ATE Test Result: Indicates the result of the unit’s final testing in production.
In units supplied with SW version 4.5 and higher should always be PASS. In
units upgraded from a version below 4.5 this parameter will be NONE.
Serial N0.: The Serial Number of the unit. Applicable only to units supplied
with SW version 4.5 and higher. In units upgraded from a version below 4.5
this parameter will be none (empty).
Feature Upgrade: A write-only text box enabling to enter a feature upgrade
license string. A feature license string to be provided by Alvarion comprises
between 32 to 64 hexadecimal digits and is MAC address dependent.