User's Manual

Chapter 4 - Operation and Administration
BreezeNET B System Manual
4-42
The default is 21 (dBm).
Transmit Power for Modulation Level 6
Valid range: -10 to 21 (dBm), using a 1dBm resolution.
The default is 21 (dBm).
Transmit Power for Modulation Level 7
Valid range: -10 to 21 (dBm), using a 1dBm resolution.
The default is 21 (dBm).
Transmit Power in RB
The Initial Transmit Power parameter defines the fixed transmit power
level when the ATPC algorithm is disabled.
If the ATPC Option is enabled the value configured for this parameter
serves for setting the initial value to be used by the ATPC algorithm
after either power up or loosing synchronization with the BU.
Transmit Power for Modulation Levels 1 to 5
Valid range: -10 to 21 (dBm), using a 1dBm resolution.
The default is 21 (dBm).
Transmit Power for Modulation Level 6
Valid range: -10 to 21 (dBm), using a 1dBm resolution.
The default is 21 (dBm).
Transmit Power for Modulation Level 7
Valid range: -10 to 21 (dBm), using a 1dBm resolution.
The default is 21 (dBm).
ATPC Parameters in BU
ATPC Option
The ATPC Option enables or disables the Automatic Transmit Power
Control (ATPC) algorithm.
The default is Enable.