User's Manual

Menus and Parameters
Manual Revision 1.0
4-13
Set Partial Operator defaults: Resets the unit to the Operator
Defaults configuration, excluding the parameters that are required
to maintain connectivity and management access. The parameters
that do not change after Set Partial Operator Defaults with
Administrator access rights are listed in Table 4-3.
Save Current Configuration As Operator Defaults
The Save Current Configuration As Operator Defaults option is available
only under Administrator access rights. It enables defining the current
configuration of the unit as the Operator Defaults configuration.
Change Unit Name
The Change Unit Name option enables changing the name of the unit,
which is also the system's name in the MIB2. The name of the unit is
also used as the prompt at the bottom of each Monitor window.
Valid values: A string of up to 32 printable ASCII characters.
The default unit name is an empty string.
Change Password
The Change Password submenu enables changing the access
password(s). A user with Installer access rights can view and change the
passwords for Read Only and Installer levels. A user with Administrator
access rights can view and change the passwords for all levels.
Valid values: A string of up to 8 printable ASCII characters
Refer to
Working with the Monitor Program, on page 4-2 for a list of the
default passwords for each of the access levels.
Flash Memory Control
The Flash Memory Control submenu enables selecting the active
software version for the unit.