User's Manual

Chapter 4 - Operation and Administration
BreezeNET B System Manual
4-2
Working with the Monitor Program
Accessing the Monitor Program Using
Telnet
1. Connect a PC to the Ethernet port, using a crossed cable.
2. Configure the PC's IP parameters to enable connectivity with the
unit. The default IP address is 10.0.0.1.
3. Run the Telnet program. The Select Access Level menu is displayed.
4. Select the required access level, depending on your specific access
rights. A password entry request is displayed. Table 4-1 lists the
default passwords for each of the access levels.
Table 4-1: Default Passwords
Access Rights Password
Read-Only public
Installer user
Administrator private
NOTE
Following three unsuccessful login attempts (using incorrect passwords), the monitor
program is blocked for several minutes. To enable access to the monitor program during
that time, the unit must be reset via SNMP or by disconnecting/reconnecting power.
5. Enter your password and press Enter. The Main Menu is displayed
as shown in Figure 4-1: . The unit type, SW version number and SW
release date displayed in the Main Menu vary according to the
selected unit and SW version.