User's Manual

Operation Verification
Manual Revision 1.0
3-9
Operation Verification
The following sections describe how to verify the correct functioning of
the Outdoor Units, Indoor Units, Ethernet connection and data
connectivity.
Outdoor Unit Verification
To verify the correct operation of the Outdoor Unit, examine the LED
indicators located on the bottom panel of the outdoor unit.
The following tables list the provided LEDs and their associated
indications.
NOTE
Verifying the correct operation of the Outdoor Unit using the LEDs, as described below,
is only possible after the configuration and alignment processes are completed.
Table 3-3: BU-ODU LEDs
Name Description Functionality
W-LINK
Wireless Link
Indictor
Green – Unit is associated with an RB
Blinking red – Unit is not associated
Off – Wireless link disabled
Status
Self-test and power
indication
Green – Power is available and
self-test passed.
Blinking Amber – Testing (not ready for
operation)
Red – Self-test failed – fatal error
ETH
Ethernet activity/
connectivity
indication
Green –Ethernet link detected.
Amber – No Ethernet connectivity between the
indoor and outdoor units.