User's Manual

Chapter 3 - Commissioning
BreezeNET B System Manual
3-2
Configuring Basic Parameters
After completing the installation process, as described in the preceding
chapter, the basic parameters must be configured to ensure that the
unit operates correctly. Once the basic parameters have been
configured, additional parameters can be remotely configured via the
Ethernet port or the wireless link using the BreezeCONFIG utility, or by
loading a configuration file.
Refer to
Working with the Monitor Program on page 4-2 for information
on how to access the Monitor program using Telnet. Refer to the
BreezeCONFIG for BreezeNET B User’s Guide for instructions on using
the configuration utility.
The Basic Configuration menu in the Monitor program includes all the
parameters necessary for the initial installation and operation of
BreezeNET B units. In many installations, most of these parameters
should not be changed from their default values. The basic parameters
and their default values are listed in Table 3-1.
Refer to
Menus and Parameters
on page 4-5 for detailed information on
the applicable parameters.
Table 3-1: Basic Parameters
Parameter Default Value Comment
IP Address 10.0.0.1
Subnet Mask 255.0.0.0
Default Gateway Address 0.0.0.0
DHCP Options Disable
Access to DHCP BU: From Ethernet Only
RB: From Wireless Only
ESSID ESSID1
Frequency (BU) 5740 MHz
Sub Band Lower Frequency (RB) 5740 MHz
Sub Band Upper Frequency (RB) 5830 MHz
Scanning Step (RB) 10 MHz