User's Manual

Appendix D - Parameters Summary
BreezeNET B System Manual
D-8
Service Parameters
Table D-7: Service Parameters
Parameter Unit Range Default Run-Time
User Filtering
Option
RB
Disable
IP Only
User Defined Addresses Only
PPPoE Protocol Only
Disable Yes
Set User Filter
Address
RB IP address (8 entries) 0.0.0.0
(all 8 entries)
Yes
Set User Filter
Mask
RB IP address (8 entries) 255.255.255.255
(all 8 entries)
Yes
Set User Filter
Range
RB 0 – 255. 0 means that the range is
not used.
0
(all 8 entries)
Yes
Security Parameters
Table D-8: Security Parameters
Parameter Unit Range Default Run-Time
Authentication
Algorithm
BU, RB
Open system
Shared Key
Open system No
Data Encryption
Option
BU, RB
Disable
Enable
Disable No
Security Mode BU, RB
WEP
AES
WEP No
Default Key RB 1-4 1 No
Key # 1 to Key
# 4
BU, RB 32 hexadecimal digits 0…0 (all 0=no
key)
No
Promiscuous
Authentication
BU
Disable
Enable
Disable Yes
(Disable
after reset)