User's Manual
Appendix D - Parameters Summary
BreezeNET B System Manual
D-2
Parameters Summary
Unit Control Parameters
Table D-1: Unit Control Parameters
Parameter Unit Range Default Run-Time
Change Unit Name BU, RB Up to 32 printable ASCII
characters
None Yes
Change Read Only
Password
BU, RB Up to 8 printable ASCII
characters
public No
Change Installer
Password
BU, RB Up to 8 printable ASCII
characters
user No
Change
Administrator
Password
BU, RB Up to 8 printable ASCII
characters
private No
SW Version FTP
File Name
BU, RB Up to 20 printable ASCII
characters
Yes
Configuration File
Name
BU, RB Up to 20 printable ASCII
characters
config.cfg Yes
Operator Defaults
File Name
BU, RB Up to 20 printable ASCII
characters
operator.cmr Yes
FTP Source Dir BU, RB Up to 80 printable ASCII
characters. Use “.” to clear.
None (empty) Yes
FTP Client IP
Address
BU, RB IP address 1.1.1.3 No
FTP Client IP Mask BU, RB IP address 255.255.255.0 No
FTP Server IP
Address
BU, RB IP address 1.1.1.4 No
FTP Gateway IP
Address
BU, RB IP address None (empty) No
FTP User Name BU, RB Up to 18 printable ASCII
characters
vx No
FTP Password BU, RB Up to 18 printable ASCII
characters
Vx No
Event Log File
Name
BU, RB Up to 20 printable ASCII
characters
logfile.log Yes
Event Log
Destination
Directory
BU, RB Up to 80 printable ASCII
characters. Use “.” to clear.
None (empty) Yes
Event Log Policy BU, RB
Message
Warning
Error
Fatal
Log None
Warning Yes
Log Out Timer BU, RB 1-999 minutes 5 Yes