Table 1-6: Radio Specifications
Item Description
Modulation
Level
4
Sensitivity
(HW Rev. A)
Sensitivity
(HW Rev. B
and higher)
Minimum SNR
1 -87 dBm -89 dBm 6 dB
2 -86 dBm -88 dBm 7 dB
3 -85 dBm -86 dBm 9 dB
4 -83 dBm -84 dBm 11 dB
5 -80 dBm -81 dBm 14 dB
6 -76 dBm -77 dBm 18 dB
7 -71 dBm -73 dBm 22 dB
Sensitivity, Minimum (dBm at
antenna port, PER<10%,
20 MHz bandwidth
3
)
8
5
-69 dBm -71 dBm 23 dB
Modulation OFDM modulation, 64 FFT points; BPSK, QPSK, QAM16, QAM64
1
The actual available frequency channels and bandwidth are defined by the selected Sub-Band, which reflects the
applicable regulatory constraints. For more details refer to section
4.2.2.4
).
2
The actual maximum available output power for each modulation level is defined by the selected Sub-Band, which
reflects the applicable regulatory constraints. For some countries the power may also be limited by limitations on
the maximum EIRP (also included in the Sub-Band parameters) and the Antenna Gain parameter. For more details
refer to section
4.2.2.4
and to section 5 4.2.6.2.8.1. For information on specific HW and Country Code limitations, see
the Country Codes document.
3
The sensitivity values are for a bandwidth of 20 MHz. When using a 10 MHz bandwidth, the sensitivity for each
modulation level is 3 dB lower. For a 5 MHz bandwidth (900 MHz band) the sensitivity for each modulation level is 6
dB lower.
4
Modulation Level indicates the radio transmission rate and the modulation scheme. Modulation Level 1 is for the
lowest radio rate and modulation scheme.
5
Modulation Level 8 is supported only in units with HW Revision B and above.