User Manual

Table Of Contents
Chapter 4 - Operation and Administration
BreezeACCESS VL System Manual
150
Signal Max SNR: The maximum SNR of signals (excluding OFDM frames with
the correct bandwidth) in the channel.
Signal Width: The average width in microseconds of signals (excluding OFDM
frames with the correct bandwidth) in the channel.
OFDM Frames: The number of OFDM frames with the correct bandwidth
detected in the channel.
OFDM SNR: The average SNR (in dB) of OFDM frames received in the
channel.
OFDM Max SNR: The maximum SNR (in dB) of OFDM frames received in the
channel.
Noise Floor Avg: The average Noise Floor (in dBm) calculated for the channel.
Noise Floor Max: The maximum Noise Floor (in dBm) calculated for the
channel.
4.2.6.2.14.7 Spectrum Analysis Information Display - Continuous
The Spectrum Analysis Information Display - Continuous option is available only
when the analysis process is active. It enables viewing the continuously updated
results of the current analysis process. The displayed information includes the
same details available for a regular Spectrum Analysis Information Display
option.
4.2.6.2.14.8 Show Spectrum analysis Parameters & Data
The Show Spectrum analysis Parameters & Data option enables viewing the
Spectrum analysis test parameters and the last test results.
4.2.6.2.15 Lost Beacons Transmission Wat c hdog T hre shold (AU only)
When it is unable to send beacon frames for a predetermined period of time, such
as in the case of interferences, the AU resets itself. The Lost Beacons
Transmission Threshold parameter represents the number of consecutive lost
beacons after which the unit will reset itself.
The range for this parameter is 100 – 1000 or 0. When the parameter is set to 0,
this feature is disabled, i.e. internal refresh will never be performed.
The default value is 218.
4.2.6.2.16 Disassociate (AU only)
The Disassociate feature enables disassociating all SUs associated with the AU or
a selected SU. This feature is useful during configuration changes, enabling to