User Manual

Table Of Contents
Menus and Parameters
Operation and Administration
149
4.2.6.2.14.1 Spectrum Analysis Channel Scan Period
The Spectrum Analysis Channel Scan Period is the period of staying on each
channel during each cycle for information gathering when performing spectrum
analysis.
Range: 2-30 seconds.
Default value: 5 seconds.
4.2.6.2.14.2 Spectrum Analysis Scan Cycles
The Spectrum Analysis Scan Cycle is the number of scanning cycles when
performing Spectrum Analysis.
Range: 1-100 cycles.
Default value: 2 cycles.
4.2.6.2.14.3 Automatic Channel Selection (AU only)
The Automatic Channel selection option defines weather the AU will choose the
best noise free channel upon startup after completion of the spectrum analysis
process. The selection is per analysis: when the analysis is completed it will be
disabled automatically.
The default is Disable.
4.2.6.2.14.4 Spectrum Analysis Activation
The Spectrum analysis Activation option enables activation of the spectrum
analysis process. Upon activation, the unit will reset automatically and start-up
in spectrum analysis mode.
4.2.6.2.14.5 Reset Spectrum Analysis Information
The Reset Spectrum Analysis Information option enables resetting the spectrum
analysis counters.
4.2.6.2.14.6 Spectrum Analysis Information Display
The Spectrum Analysis Information Display option enables viewing the results of
the last analysis process. The displayed information includes the following details
for each channel:
Frequency in MHz
Signal Count: The number of signals (excluding OFDM frames with the
correct bandwidth) in the channel.
Signal SNR: The average SNR of signals (excluding OFDM frames with the
correct bandwidth) in the channel.