User's Manual

breezeAccessVLMib
BreezeACCESS VL System Manual
237
MIB Parameter Description Value/Range
*ServiceParameters
(breezeAccessVLMib 7)
Applicable to all units.
Service parameters.
*MirDownlink
(*ServiceParameters 2)
Applicable to SU/RB. The
Maximum Information Rate
(MIR) from AU/BU to
SU/RB. MIR must be above
brzaccVLCirDownlink value.
Integer
Range for Set:
SU-3 with SW version below
4.0: 128 – 2,048 (Kbps)
SU-3 with SW version 4.0 or
higher: 128 – 3,072 (Kbps)
SU-6 with SW version below
4.0: 128 – 3,968 (Kbps)
SU-6 with SW version 4.0 or
higher: 128 – 6,016 (Kbps)
SU-54: 128 – 53,888 (Kbps)
SU-I: 128 – 6,016 (Kbps)
RB-14: 128 – 6,912 (Kbps)
RB-28: 128 – 22,016 (Kbps)
RB-100: 128-107,904 (Kbps)
The actual value (Get) will be
the entered value rounded to
the nearest multiple of 128
(N*128)
*MirUplink
(*ServiceParameters 3)
Applicable to SU/RB. The
Maximum Information Rate
(MIR) from SU/RB to
AU/BU. MIR must be above
brzaccVLCirUplink value.
Integer
Range for Set:
SU-3 with SW version below
4.0: 128 – 2,048 (Kbps)
SU-3 with SW version 4.0 or
higher: 128 – 3,072 (Kbps)
SU-6 with SW version below
4.0: 128 – 3,968 (Kbps)
SU-6 with SW version 4.0 or
higher: 128 – 6,016 (Kbps)
SU-54: 128 – 53,888 (Kbps)
SU-I: 128 – 2,048 (Kbps)
RB-14: 128 – 6,912 (Kbps)
RB-28: 128 – 22,016 (Kbps)
RB-100: 128-107,904 (Kbps)
The actual value (Get) will be
the entered value rounded to
the nearest multiple of 128
(N*128)
*CirDownlink
(*ServiceParameters 4)
Applicable to SU only. Not
applicable to BreezeNET B
products. The Committed
Information Rate (CIR) from
AU to SU.
CIR must be below
brzaccVLMirDownlink value.
Integer
Range for Set:
SU-3 with SW version below
4.0: 0 – 2,048 (Kbps)
SU-3 with SW version 4.0 or
higher: 0 – 3,072 (Kbps)
SU-6 with SW version below
4.0: 0 – 3,968 (Kbps)
SU-6 with SW version 4.0 or
higher: 0 – 6,016 (Kbps)
SU-54: 0 – 45,056 (Kbps)
SU-I: 0 –6,016 (Kbps)
The actual value (Get) will be
the entered value rounded to
the nearest multiple of 128
(N*128).
BreezeNET B products will
return 65535 for na.
*CirUplink
(*ServiceParameters 5)
Applicable to SU only. Not
applicable to BreezeNET B
products. The Committed
Integer
Integer
Range for Set: