User's Manual
breezeAccessVLMib
BreezeACCESS VL System Manual
215
MIB Parameter Description Value/Range
Data Encryption Option. notSupported (2)
*AESEncryptionSupport
(CountryDependentParameters 5)
Applicable to all units.
Read only. The supported
AES Encryption Option.
Integer
supported (1)
notSupported (2)
*AntennaGainChange
(*SysInfo 19)
Applicable to all units.
Indicates whether the
Antenna Gain parameter is
changeable of fixed.
Integer
supported (1)
notSupported (2)
E.2.2 Unit Control Parameters
MIB Parameter Description Value/Range
*UnitControl
(breezeAccessVLMib 2)
*ResetUnit
(*UnitControl 1)
Applicable to all units. Resets the
unit and applies new parameter
values.
Integer
cancel (1)
resetSystemNow (2)
*SetDefaults
(*UnitControl 2)
Applicable to all units. Sets unit
configuration to Defaults values
after the next reset.
completeFactory: All parameters
revert to Factory Defaults values
partialFactory: All parameters
revert to Factory Defaults values,
except the parameters required
for maintaining wireless
connectivity.
completeOperator: All parameters
revert to Operator Defaults values
partialOperator: All parameters
revert to Operator Defaults
values, except the parameters
required for maintaining wireless
connectivity.
Integer
NoDefaultSettingRequested (0),
completeFactory (1)
partialFactory (2)
completeOperator (3)
partialOperator (4)
cancelCurrentPendingRequest
(5)
*UnitName
(*UnitControl 3)
Applicable to all units. The unit
name.
DisplayString (SIZE(32))
A string of up to 32 printable
ASCII characters.
*FlashMemoryControl
(*UnitControl 4)
Applicable to all units.
Reset And Boot From Shadow
Version: Activates the shadow
version.
Use Running Version After Reset:
The currently active version will
become the main version and will
be activated after next reset.
Integer
resetAndBootFrom
ShadowVersion (1)
useRunningVersion
AfterReset (2)
cancel (3)
*TelnetLogoutTimer
(*UnitControl 5)
Applicable to all units. Time-out of
management via Telnet.
Automatic exit if the program is
inactive for the defined time.
Integer
1-999 (minutes)
*SaveCurrentConfigurationAs
OperatorDefaults
(*UnitControl 6)
Applicable to all units. Saves the
current configuration as Operator
Defaults.
Integer
saveAsDefaults (1)
cancel (2)
*ExitTelnet
(*UnitControl 7)
Applicable to all units. Exit the
Telnet Monitor session.
Integer
cancelOperation (1)
exit (2)
*UnitPasswords Applicable to all units. Unit